
- OCT (Optical Coherence Tomography) ermöglicht präzise Steuerung und Kontrolle des refraktiven Eingriffs - Deutlich weniger Gewebeverluste als bei vergleichbaren Laser-Technologien (Reduktion um rund 60%) - Hohe Vorhersagbarkeit des Operationsergebnisses - Erster Femtosekundenlaser, der die offizielle Zulassung für den Einsatz in der Kataraktchirurgie erhalten hat

- The most modern femtosecond laser for eye laser treatments on the market.
- The mechanical microkeratome is replaced by the laser; during LASIK eye laser treatment,
no blade will touch a patient's eyes again.
- Safe and accurate eye laser surgery with even less complications during and after a LASIK
eye laser treatment.
- Painless eye laser treatment with no risk of damaging the upper corneal layer.

The excellent Excimer laser from the US offers advantages especially accompanied by
the wavefront guided laser treatment with LASIK:
- Variable laser spot (VSSTm): Tissue and time saving abrasion, thanks to the
variable diameter of the laser beam (0.65 mm - 6 mm).
- Variable laser frequency (VRRTm): Time saving, due to the laser frequency adaption
to the spot size.
- Active 3D eye tracking system: Automatic centering of the treatment zone on the
centre of the pupil, due to iris recognition, and thereby compensating movements
and cyclotorsion (rolling of the eye ball).
- Even more reduced rate of subsequent treatment after the eye laser surgery
with LASIK, due to the most modern wavefront technology.

- The Technolas 217Z/100 excimer laser was constructed for the laser treatments in a way
that the LASIK surgeries could be carried out optimally and efficiently for patients as well
as for surgeons: The patient can easily be reached during the LASIK procedure.
- The newest generation of the Flying Spot laser: Ensuring the high accuracy of the LASIK
eye laser treatment with gentle corneal ablation.
- Fastest eye tracker system: Ensures that the position of the eye is permanently controlled,
and that the laser pulse is controllable accordingly.

- Newest excimer laser with high pulse rate (500 Hz) for LASIK eye laser treatments.
- Guarantees a highly accurate and tissue gentle laser treatment.
- The integrated 1,050 Hz eye tracker enables an extremely precise positioning of each laser
impulse of less than 3 milliseconds during a LASIK laser treatment.

- Wavefront measurements of the entire eye for laser treatments, low (short-, and longsightedness,
along with astigmatism) as well as high aberrations (distortion aberrations).
- Developing a "fingerprint" of the optical system by calculating the wavefront for each point of
measurement, based on the Fourier Analysis.
- Calculating the optimal ablation with the wavescan software for the wavefront guided LASIK eye
laser treatment.

- Graphic illustration of the anterior and posterior corneal surface.
- Determination of the corneal thickness.
- More than 1,000 surface points is measured in less than 6 seconds.

- Wavefront meter, enabling the wavefront guided LASIK eye laser treatment.
- The Zyoptix 100 system can recognise and measure the individual refractive power.
- More than 1,000 points are recognised and a three-dimensional image is created.
- Especially patients with night vision problems or with reduced contrast sensitivity profit from this.

- More precise flap thickness (120, 140, or 160 ¬μm).
- Both nasal and upwards flap hinge is possible. In case of a dry eye, a LASIK nasal hinge is more
advantageous.
- Constantly thin flaps (tissue gentle, saves corneal tissue).
- Right/left switch: rapid switching when moving from one eye to the other.
- Smoother cut surface - Better for deep-set eyes and narrow lid fissure.

- The Procyon Pupillometer measures the pupil size in a dusk situation, in the dark, and in the daylight.
- It supports the planning of a LASIK surgery: The ablation zone of the laser should consider the pupil size.
- Helps prevent postoperative problems, such as halos, etc.

- The Pentacam measures the front of the eye with a rotating Scheimpflug camera.
- The non-contact measurement lasts a couple of seconds and captures the different levels of the eye in 50 images.
- Depth measurement of the anterior chamber of the eye. Determines the corneal thickness and topography;
Also sectional images through the cornea is presentable.
- Additionally, thickness and transparency of the lens can be determined.
x Close
The protection of your personal data during your visit to our website is very important to us, EuroEyes Deutschland GmbH. We can therefore guarantee you that collecting, processing and use of data are handled according to the data protection regulations. In the following, we would like to briefly outline our basic principles governing our use of your personal data:
1. Links to Websites Operated by Other Providers
Our website may contain links to websites operated by other providers. These third-party websites are not covered by this privacy policy, they have their separate and independent privacy policies. We therefore have no responsibility or liability for the content and activities of these linked sites.
2. The Collection Processing and Utilisation of our Website
You can always access our website without disclosing any personal data to us. When you visit our website, our web server automatically records your IP-address, the website from which you visit us, and the web pages within our website you actually visit. This information is gathered and analysed for statistical and optimisation purposes. The data will not be used to identify visitors to this website personally. We will never provide any data to third parties. Personal data will only be collected, processed and utilised if you provide them to us voluntarily. We will particularly use your personal data to carry out the following services and offers selected by you
• Request for an examination
• Inquiry "Am I suitable?"
• Request for a return call
• Request for an appointment
• To sign up for an information evening
• Request for information material
The list of the above mentioned services and offers can, in accordance with section 8 of this privacy policy, at any point be constrained or extended by us. The type, scope and purpose of the data collection, processing and utilisation of the personal data, that you provide us with (e.g. name, address, phone number, email address etc.), derive from specified entry and contact forms. Please understand that we require your personal information for the use of some offers and services. The obliged data is marked with a *. It is of course up to you if you do not choose not to provide us with certain information, but this can result in some of our offers and services not being available for you. We use the data communicated by you for the fulfilment and completion of your request and for handling additional above-mentioned contact requests and orders. After fulfilling your request your data will be locked for further processing and deleted after fulfilling the requirements by tax and trade laws, unless you have explicitly agreed to further utilisation.
3. The Transmission of Personal Data to Third Parties
We use the data communicated by you for the fulfilment and completion of your request, and pass on the data to the involved EuroEyes companies and eye laser centres in Germany. A passing of your data to other third parties will not take place, unless you have given your express consent, or unless we are obliged by the law or a court judgement to disclose and communicate the data.
4. Advertisement and Market Research
When you provide us with your address details (name and zip code) for the justification, implementation and completion of the contractual relationship, we may use this information to inform you about new offers or for market research purposes. You can object to or withdraw your permission for the processing and forwarding and other use of your data for marketing purposes at any time by informing:
EuroEyes Deutschland GmbH
represented by the CEO Dr. Jørn Jørgensen
Elbchaussee 454
22587 Hamburg Germany
Court of jurisdiction: Hamburg, HRB No. 85711
Value added tax identification number: DE 227128743
Phone: +49 0800 / 17 11 17 11
Fax: +49 (0) 40 / 86 64 88-722
Online Contact:info@euroeyes.de
We will only contact you e.g. via email, phone, or text message, if you have given your consent. Information material will be sent to the email address you provided if you selected the checkbox next to "Free information pack" or "Please send a free information kit".
5. Technical Measures to Protect Your Data
 We deploy technical and organisational security measures to protect the information you have made available from being manipulated unintentionally or intentionally, lost, destroyed, or accessed by unauthorised persons. Your personal data will be transmitted in encrypted form to prevent misuse by third parties. Our security measures are being improved continuously in accordance with the technological development. In spite of regular controls, complete protection against all risks is not possible.
6. Use of Cookies
We use cookies to track visitor preferences and to be able to design our web pages as optimally as possible. Cookies are small files that are temporarily stored on your hard disk during your visit (the socalled Session Cookies). The information contained in these cookies is used to facilitate navigation and allow a high degree of user-friendliness. You can, of course, also view our website without cookies. Our cookies do not contain any personal information, ensuring that your private domain remains protected. Most browsers accept cookies automatically. You can disable cookies by following the instructions of your browser's privacy and security preferences feature. To learn how to do this for your specific browser, please refer to the manufacturer's instructions for your browser. If, however, you choose not to accept cookies, this can limit the functions available to you on our sites.
7. Information on Saved Data, Rectification, Blocking, and Deletion
According to the Federal Law of data protection you can ask for stored information at any time and you also have the right to ask for personal data to be modified, closed or to be deleted. In the event of questions regarding the collection, processing or use of your personal data and for information, the amendment, blocking or deletion of data, and the revocation of consents granted, please contact:
EuroEyes Deutschland GmbH
represented by the CEO Dr. Jørn Jørgensen
Elbchaussee 454
22587 Hamburg
Germany
Online Contact:info@euroeyes.de
8. Changes to the Privacy Policy
We reserve the right to change this privacy policy statement at any time in compliance with existing legislation on data protection.
Edited: 05.04.2011


